ClockOutputDevice¶
A Bonsai sink that wraps a FMC Host Clock Output Device device.
- Inputs
A
boolean
that is connected to theEnable
setting and can be use to gate the clock output, but is not required.- Outputs
None
Configuration¶
Configuration is performed using the property pane which contains the following options.
Name |
Type |
Description |
---|---|---|
ClockEnabled |
boolean |
If true the clock output is enable and disabled if false. This can be controlled from within the workflow using the boolean input. |
Frequency |
double |
Output clock frequency in Hz |
DutyCycle |
double |
Output clock duty cycle (percent) |
Delay |
double |
If SyncToRun is true, this determins the delay from the start of the hardware running state to the start of the clock output in seconds. |
SyncToRun |
bool |
If true, then the clock output will remain low until hardware aquisition starts. Otherwise it will free run independent of acqusition state. |